Degradation of Thermally Aged Insulation Paper in Mixed Polyol Ester and Used Mineral Oil

Authors

  • Abdul Rajab Universitas Padjadjaran, Indonesia
  • Emilliano Emilliano Universitas Padjadjaran, Indonesia
  • Darmawan Hidayat Universitas Padjadjaran, Indonesia
  • Mohammad Taufik Universitas Padjadjaran, Indonesia
  • Mohamad Kamarol Mohd Jamil University Sains Malaysia, Malaysia
  • Hidayatul Fadli PT. Paragon Technology and Innovation, Indonesia

DOI:

https://doi.org/10.25077/aijaset.v6i2.350

Abstract

This study investigates the mechanical, chemical, and microstructural changes of thermally aged transformer insulation paper in polyol ester and its mixtures with residual used mineral oil. The mixture was intended to simulate retrofilling conditions where complete removal of aged mineral oil from transformers cannot be ideally achieved. The proportions of used mineral oil in the mixtures are 0, 2.5, 5.0, and 7.5% by volume. Kraft paper, cut into approximately 45 cm × 20 cm, was wrapped around 9 g of copper conductor, immersed in about 1000 ml of oil mixture to imitate real transformer conditions. Samples were aged in an oven at 140 °C for 14 and 28 days. The results demonstrate that the chemical and physical integrity of the insulation paper, with tensile strength, FTIR, and SEM analyses consistently indicating increasing cellulose degradation, oxidation, and fiber damage at higher used mineral oil concentrations and longer aging durations. In addition to assessing degradation, the study highlights that hydrolysis of polyol ester generates long-chain fatty acids capable of esterifying cellulose. This reaction contributes to improved paper insulation’s thermal stability by slowing depolymerization and limiting further fiber damage. Conversely, the presence of used mineral oil accelerates cellulose deterioration.

Author Biographies

Abdul Rajab, Universitas Padjadjaran, Indonesia

Department of Electrical Engineering, Universitas Padjadjaran, Indonesia

Emilliano Emilliano, Universitas Padjadjaran, Indonesia

Department of Electrical Engineering, Universitas Padjadjaran, Indonesia

Darmawan Hidayat, Universitas Padjadjaran, Indonesia

Department of Electrical Engineering, Universitas Padjadjaran, Indonesia

Mohammad Taufik, Universitas Padjadjaran, Indonesia

Department of Electrical Engineering, Universitas Padjadjaran, Indonesia

Mohamad Kamarol Mohd Jamil, University Sains Malaysia, Malaysia

School of Electrical & Electronic Engineering, University Sains Malaysia, Malaysia

Hidayatul Fadli, PT. Paragon Technology and Innovation, Indonesia

PT. Paragon Technology and Innovation, Indonesia

References

[1]. N. Seifaddini et al., “Aging characterization of thermally aged transformer paper based on its reflectance,” Results Opt., vol. 16, Jul. 2024.

[2]. L. Fu, H. Li, Y. Deng, and C. Tang, “The influence of small molecule products on natural ester impregnated cellulose insulation paper under electric-thermal coupling field,” Colloids Surfaces A Physicochem. Eng. Asp., vol. 697, Sep. 2024.

[3]. C. M. Gutierrez, A. O. Fernandez, C. J. Renedo Estebanez, C. O. Salas, and R. Maina, “Understanding the Ageing Performance of Alternative Dielectric Fluids,” IEEE Access, vol. 11, pp. 9656–9671, February, 2023.

[4]. K. M. L. Gmati, Ghada; Fofana, Issouf; Picher Patrick; Fernandez, Oscar Henry Arroyo; Rebaine, Djamal; Meghnefi, Fethi; Brahami, Youssouf; Yapi, “Efect of Moisture and Aging of Kraft Paper Immersed in Mineral Oil and Synthetic Ester on Bubbling Inception Temperature in Power Transformers,” Energies, vol. 18, 2025.

[5]. M. N. Lyutikova, S. M. Korobeynikov, U. M. Rao, and I. Fofana, “Mixed Insulating Liquids with Mineral Oil for High-Voltage Transformer Applications: A Review,” IEEE Trans. Dielectr. Electr. Insul., vol. 29, no. 2, pp. 454–461, Apr. 2022.

[6]. I. Fernández, “The Need for Experimental and Numerical Analyses of Thermal Ageing in Power Transformers,” Energies, vol. 15, no. 17, 2022.

[7]. P. Rozga, A. Beroual, P. Przybylek, M. Jaroszewski, and K. Strzelecki, “A review on synthetic ester liquids for transformer applications,” Energies, vol. 13, no. 23, Dec. 2020.

[8]. J. Sanz, C. J. Renedo, A. Ortiz, P. J. Quintanilla, F. Ortiz, and D. F. García, “A Brief Review of the Impregnation Process with Dielectric Fluids of Cellulosic Materials Used in Electric Power Transformers,” MDPI, May 01, 2023.

[9]. M. G. Danikas and R. Sarathi, “Alternative Fluids-with a Particular Emphasis on Vegetable Oils-as Replacements of Transformer Oil A Concise Review,” 2020.

[10]. C. Fernández-Diego, A. Ortiz, I. A. Carrascal, I. Fernández, and C. J. Renedo, “Kinetic assessment of mechanical properties of a cellulose board aged in mineral oil and synthetic ester,” Polymers (Basel)., vol. 13, no. 23, pp. 1–19, 2021.

[11]. P. Zukowski, P. Rogalski, V. Bondariev, and M. Sebok, “Diagnostics of High Water Content Paper-Oil Transformer Insulation Based on the Temperature and Frequency Dependencies of the Loss Tangent,” Energies, vol. 15, no. 8, pp. 1–16, 2022.

[12]. B. García, A. Ortiz, C. Renedo, D. F. García, and A. Montero, “Use performance and management of biodegradable fluids as transformer insulation,” Oct. 01, 2021.

[13]. J. Hao, J. Zhang, W. Ye, R. Liao, and L. Yang, “Development of Mixed Insulation Oil as Alternative Liquid Dielectric: A Review,” CSEE J. Power Energy Syst., vol. 10, no. 3, pp. 1242–1258, May 2024.

[14]. M. Fasehullah, F. Wang, S. Jamil, and M. S. Bhutta, “Influence of Emerging Semiconductive Nanoparticles on AC Dielectric Strength of Synthetic Ester Midel7131 Insulating Oil,” Materials (Basel)., vol. 15, no. 13, Jul. 2022.

[15]. A. Rajab, A. Ardison, R. W. Pratama, R. Novendra, B. Baharuddin, and T. Artono, “Dissolved Gas Analysis of Methyl EsterMineral Oil Mixture Under Partial Discharge,” TEM J., vol. 14, no. 1, pp. 55–63, 2025.

[16]. S. O. Oparanti, U. M. Rao, and I. Fofana, “Natural Esters for Green Transformers: Challenges and Keys for Improved Serviceability,” MDPI, Jan. 01, 2023.

[17]. D. Silalahi, H. Hermansyah, and P. Cognet, “Comparative Study on the Performance of Ester Oil for Transformer Retrofilling,” Int. J. Technol., vol. 16, no. 5, pp. 1752–1771, 2025.

[18]. M. Feng, Dawe; Hao, Jian; Liao, Ruijin; Chen, Xin; Cheng, Lin; Liu, “Comparative Study on the Thermal-Aging Characteristics of Cellulose Insulation Polymer Immersed in New Three-Element Mixed Oil and Mineral Oil,” Polymers (Basel)., vol. 11, 2019.

[19]. R. K. Rao, U. Mohan; Sood, Yog Raj; Jarial, “Physiometric and Fourier Transform Infrared Spectroscopy Amalysis of Cellilose Insulation in Blend of Mineral and Synthetic Ester Oil for Transformers,” IET Sci. Meas. Technol., vol. 11, no. 3, pp. 297–304, 2016.

[20]. T. Münster, P. Werle, K. Hämel, and J. Preusel, “Thermally accelerated aging of insulation paper for transformers with different insulating liquids,” Energies, vol. 14, no. 11, Jun. 2021.

[21]. C. Fernandez-Diego, A. Ortiz, I. A. Carrascal, I. Fernandez, F. Delgado, and C. Olmo, “Kraft and Diamond Dotted Paper Thermally Aged in Mineral Oil and Natural Ester: Mechanical Characterisation,” in Proceedings - IEEE International Conference on Dielectric Liquids, IEEE Computer Society, Jun. 2019.

[22]. Suwarno and R. A. Pasaribu, “Thermal aging of mineral oil-paper composite insulation for high voltage transformer,” Int. J. Electr. Eng. Informatics, vol. 8, no. 4, pp. 819–834, 2016.

[23]. I. S. Chairul, N. H. Rahim, S. A. Ghani, M. S. A. Khiar, M. S. Johal, and M. N. M. Din, “Compatibility of transformer construction materials with mineral, natural ester, and synthetic ester insulating oils,” Bull. Electr. Eng. Informatics, vol. 14, no. 3, pp. 1639–1646, Jun. 2025.

[24]. A. Montero, B. García, and C. López, “Life Expectancy of Transformer Paper Insulation Retrofilled with Natural Ester in the Laboratory,” Polymers (Basel)., vol. 15, no. 22, Nov. 2023.

[25]. K. J. Rapp, C. P. McShane, and J. Luksich, “Interaction mechanisms of natural ester dielectric fluid and Kraft paper,” 2005 IEEE Int. Conf. Dielectr. Liq. ICDL 2005, pp. 393– 396, 2005.

[26]. B. García, T. García, V. Primo, J. C. Burgos, and D. Urquiza, “Studying the loss of life of natural-ester-filled transformer insulation: Impact of moisture on the aging rate of paper,” IEEE Electr. Insul. Mag., vol. 33, no. 1, pp. 15–23, 2017.

[27]. O. H. Arroyo, J. Jalbert, I. Fofana, and M. Ryadi, “Temperature dependence of methanol and the tensile strength of insulation paper: kinetics of the changes of mechanical Electr. Insul., vol. 23, no. 1, pp. 246–257, properties during ageing,” Cellulose, vol. 24, 2016, doi: 10.1109/TDEI.2015.004744. no. 2, pp. 1031–1039, 2017.

[28]. K. Bandara, C. Ekanayake, T. K. Saha, and P. K. Annamalai, “Understanding the ageing aspects of natural ester based insulation liquid in power transformer,” IEEE Trans. Dielectr. Electr. Insul., vol. 23, no. 1, pp. 246–257, 2016.

[29]. P. Przybylek, “Thermal Ageing of Dry Cellulose Paper Impregnated with Different Insulating Liquids—Comparative Studies of Materials Properties,” Energies, vol. 17, no. 4, 2024.

Downloads

Published

2026-07-23

How to Cite

Rajab, A., Emilliano, E., Hidayat, D., Taufik, M., Jamil, M. K. M., & Fadli, H. (2026). Degradation of Thermally Aged Insulation Paper in Mixed Polyol Ester and Used Mineral Oil. Andalasian International Journal of Applied Science, Engineering and Technology, 6(2), 251–259. https://doi.org/10.25077/aijaset.v6i2.350

Issue

Section

Articles