Analysis of The Effect of Bank Capacitor Placement as Voltage Drop Increase in Distribution Network

Authors

  • Muhammad Yudha Rofandy Universitas Malikussaleh
  • Arnawan Hasibuan Universiti Malaysia Perlis
  • Rosdiana Rosdiana Universitas Malikussaleh

DOI:

https://doi.org/10.25077/aijaset.v2i1.32

Abstract

The quality of electricity distribution in the distribution network is an important thing that must be considered. To maintain the quality of electrical energy, there are several parameters that must be considered in the distribution network, including voltage drop, power losses, power factor and other factors. One of the solutions used to improve the voltage drop and power factor is to install a capacitor bank in the distribution network. This paper will discuss the placement of capacitor banks using the fuzzy logic method with inputs in the form of voltage profiles, power losses and power flow calculations using ETAP 12.6.0 software. In the Rao feeder, the final voltage is 16.806 kV or has passed the standard set by PLN (-10% and +5%). The Rao feeder has a power loss of 0.242 MW and a power factor of 0.7815. Fuzzy logic method is used to determine the optimal location of capacitor placement. After the installation of the capacitor bank, the terminal voltage increases and the total power loss decreases, while the power factor increases. From the results obtained, PLN as a supplier of electrical energy can reduce power losses by placing and installing capacitor banks in the distribution network.

Author Biographies

Muhammad Yudha Rofandy, Universitas Malikussaleh

Department of Electrical Engineering

Arnawan Hasibuan, Universiti Malaysia Perlis

School of Electrical System Engineering, Universiti Malaysia Perlis, Malaysia

Rosdiana Rosdiana, Universitas Malikussaleh

Department of Electrical Engineering

References

F. R. Fan, W. Tang, and Z. L. Wang, “Flexible Nanogenerators for Energy Harvesting and Self-Powered Electronics,” Adv. Mater., vol. 28, no. 22, pp. 4283–4305, Jun. 2016, doi: 10.1002/ADMA.201504299.

“Losses in Distribution & Transmission Lines | Electrical India Magazine on Power & Electrical products, Renewable Energy, Transformers, Switchgear & Cables.” https://www.electricalindia.in/losses-in-distribution-transmission-lines/ (accessed Jan. 29, 2022).

L. Ochoa, A. Keane, G. H.-I. T. on Power, and undefined 2011, “Minimizing the reactive support for distributed generation: Enhanced passive operation and smart distribution networks,” ieeexplore.ieee.org, 2011, doi: 10.1109/TPWRS.2011.2122346.

J. Mendoza, D. Morales, R. L.-… on P. Systems, and undefined 2007, “Multiobjective location of automatic voltage regulators in a radial distribution network using a micro genetic algorithm,” ieeexplore.ieee.org, Accessed: Jan. 29, 2022. [Online]. Available: https://ieeexplore.ieee.org/abstract/document/4077126/.

M. Ghiasi, J. O.- Complexity, and undefined 2016, “Optimal capacitor placement to minimizing cost and power loss in Tehran metro power distribution system using ETAP (A case study),” Wiley Online Libr., vol. 21, pp. 483–493, Nov. 2016, doi: 10.1002/cplx.21828.

F. Blaabjerg, Z. Chen, S. K.-I. transactions on power, and undefined 2004, “Power electronics as efficient interface in dispersed power generation systems,” ieeexplore.ieee.org, Accessed: Jan. 29, 2022. [Online]. Available: https://ieeexplore.ieee.org/abstract/document/1331479/.

M. Radzi, N. R.-I. T. on Industrial, and undefined 2009, “Neural network and bandless hysteresis approach to control switched capacitor active power filter for reduction of harmonics,” ieeexplore.ieee.org, Accessed: Jan. 29, 2022. [Online]. Available: https://ieeexplore.ieee.org/abstract/document/4776494/.

H. Hindersah, A. Purwadi, … F. A.-P. of the, and undefined 2011, “Prototype development of single phase prepaid KWh meter,” ieeexplore.ieee.org, Accessed: Jan. 29, 2022. [Online]. Available: https://ieeexplore.ieee.org/abstract/document/6021692/.

A. Hasibuan, M. Isa, M. I. Yusoff, S. R. Abdul Rahim, and I. M. A. Nrartha, “Effect of installation of distributed generation at different points in the distribution system on voltage drops and power losses,” AIP Conf. Proc., vol. 2339, May 2021, doi: 10.1063/5.0044192.

S. Joyal Isac and K. Suresh Kumar, “Optimal capacitor placement in radial distribution system to minimize the loss using fuzzy logic control and hybrid particle swarm optimization,” Lect. Notes Electr. Eng., vol. 326, pp. 1319–1329, 2015, doi: 10.1007/978-81-322-2119-7_128.

A. McBratney, B. Minasny, S. Cattle, R. V.- Geoderma, and undefined 2002, “From pedotransfer functions to soil inference systems,” Elsevier, Accessed: Jan. 29, 2022. [Online]. Available: https://www.sciencedirect.com/science/article/pii/S0016706102001398.

M. Meiriyanti, S. S.-J. E. Elektrik, and undefined 2018, “PENGARUH PENEMPATAN KAPASITOR BANK PADA TRAFO DISTRIBUSI JARINGAN 20 KV DALAM PERBAIKAN FAKTOR DAYA (Studi Kasus Pada,” repository.unimal.ac.id, vol. 7, 2018, Accessed: Jan. 29, 2022. [Online]. Available: https://repository.unimal.ac.id/4428/1/Paper 5 terbitan April 2018.pdf.

Downloads

Published

2022-03-22

How to Cite

Rofandy, M. Y. ., Hasibuan, A., & Rosdiana, R. (2022). Analysis of The Effect of Bank Capacitor Placement as Voltage Drop Increase in Distribution Network. Andalasian International Journal of Applied Science, Engineering and Technology, 2(1), 11–24. https://doi.org/10.25077/aijaset.v2i1.32

Issue

Section

Articles